Common problem

Injection molding machine common fault treatment method

2024-10-07 09:33:09 Injection molding machine

First, the oil pump motor and oil pump start, but not pressure.

1. The proportional valve on the oil pump is loose or the coil is burned - check whether the proportional pressure valve is energized.

2. Impurities block the oil port of the proportional pressure valve on the oil pump -- remove the proportional pressure valve to 

remove impurities.

3. The pressure oil is unclean, the debris accumulates on the surface of the oil filter, preventing the pressure oil from entering the 

pump - clean the oil filter and replace the pressure oil.

4. Oil leakage inside the oil pump, caused by too long use, internal loss or pressure oil unclean damage - repair or replace the oil 

pump.

5. Oil spillage barrels, oil pipes and joints - eliminate leakage areas.

6. Oil business card printing dead - check whether the oil spool activity is normal.

injection mould


Second, the melting tube temperature can not be controlled

1. If the temperature cannot be controlled, check whether the contact of the electric heating contactor is sticky, and whether the wire of the thermocouple is loose or damaged.

2. If the temperature cannot rise, check whether the electric heating air switch in the electric box is off, whether the contactor and relay are drawn, whether there is voltage, whether the insurance is burned out, and whether the heating ring is burned out.

3. Check whether the thermometer is damaged.


Three, no mold locking

1. Whether the front opening safety door has been closed, whether the stopper of the safety door has been pressed and loosened 

by the safety door, and whether the wiring is loose or damaged.

2. The mode-locked solenoid coil may have moved inside the valve and stuck the spool -- clean or replace the mode-locked mold 

opening control valve.

3. Direction valve may be out of position - Clean the direction valve.

4. The thimble cannot be returned to reset -- check whether the thimble works normally.

5. Check whether the origin of the mode-locking and mode-opening electronic ruler of the computer controller has changed and 

whether the mode-locking position has terminated.

6. Check whether the pressure gauge works.

7. Press the mode-locking key to see whether the display displays mode-locking signals or other signals and alarms.

8. Check whether the position, speed and pressure of the mold lock are adjusted normally.

9. Check whether the clamping piston rod is broken.


Four, do not shoot glue

1. The coil of the injection solenoid system may have been burned, or there are foreign objects entering the direction valve, and the 

valve core is stuck to move - clean or replace the injection valve.

2. The pressure is too low -- adjust the pressure of the high jet glue.

3. The temperature of injection molding is too low - adjust the thermometer to increase the temperature to the required point, such 

as adjusting the thermometer still can not increase the temperature, check whether the electric heater and fuse are burned out

Or loose break, if broken, timely replacement.

4. The injection combination valve opening system connection is loose or poor contact - the combination switch wire connector is 

properly connected.


Fifth, the glue screw rotates, but the rubber material does not enter the barrel

1. The melt back pressure is too high, the back pressure valve is damaged or improperly adjusted -- adjust or replace the melt back 

pressure valve.

2. Insufficient water transport, so that the temperature is too high, so that the rubber particles into the screw is blocked - adjust the 

water transport, take out the bonded rubber block. See if the water conveyor is blocked or has no cooling water

3. There is no material in the bucket - add material.

4. Whether the melt tube temperature is too high.


Six. The shooting platform does not move

1. The moving limit travel switch of the shooting platform is pressed by the adjusting ram - adjust.

2. The coil of the shooting platform moving solenoid valve may be burned or there are foreign objects entering the direction valve 

stuck in the spool to move - clean or replace the solenoid valve.

3. Check the forward speed of the shooting platform and whether the pressure is improperly adjusted.

4. Check the 1/0 board, the direction valve output voltage (DC+24V) is normal, if not normal, check the corresponding output 

transistor or relay is damaged.

5. Press the station key to check whether the computer display displays the signal in front of the station, or other signals and alarms.

6. Check whether the pressure gauge works.

injection mould


Home
Product
News
Contact
主站蜘蛛池模板: 夜夜春夜夜爽| 中文字幕无码精品亚洲资源网久久| 国产精品久久久十八禁| 亚洲国产精品久久久久婷婷老年 | 免费看无码特级毛片| 亚洲国产成人精品无码区二本| 成人做受黄大片| 成全免费高清动漫电影| 老熟女高潮喷水了| 精品人妻少妇一区二区三区不卡| 中文字幕aⅴ人妻一区二区| 乱人伦人妻中文字幕无码| 国产乱子伦视频在线观看| 国产精品亚洲综合色区韩国| 亚洲成av人的天堂在线观看| 女人腿张开让男人桶爽| 国产乱人伦app精品久久| 1000部啪啪未满十八勿入下载| 成年美女黄网站18禁免费| 性一交一乱一伦一色一情孩交| 欧美寡妇xxxx黑人猛交| 亚洲av无码av日韩av网站| 第一次挺进苏雨瑶的身体| 无码gogo大胆啪啪艺术| 久久人人爽爽爽人久久久| 亚洲v无码一区二区三区四区观看| 人妻互换免费中文字幕| 人妻奶水人妻系列| 免费无码成人片| 亚洲 日韩 激情 无码 中出 | 99re久久精品国产| 欧美成人aaa片一区国产精品| 国产成人精品日本亚洲11| 意大利xxxx性hd极品| 我故意没有穿内裤坐公车让视频| 2021久久精品国产99国产精品| 亚洲欧美中文日韩v在线观看| 久久无码人妻精品一区二区三区| 国产无遮挡吃胸膜奶免费看| 伊人色综合久久天天五月婷| 国产精品久久久久9999赢消 |