Injection molding machine common fault treatment method

2024-10-07 09:33:09 Injection molding machine

First, the oil pump motor and oil pump start, but not pressure.

1. The proportional valve on the oil pump is loose or the coil is burned - check whether the proportional pressure valve is energized.

2. Impurities block the oil port of the proportional pressure valve on the oil pump -- remove the proportional pressure valve to 

remove impurities.

3. The pressure oil is unclean, the debris accumulates on the surface of the oil filter, preventing the pressure oil from entering the 

pump - clean the oil filter and replace the pressure oil.

4. Oil leakage inside the oil pump, caused by too long use, internal loss or pressure oil unclean damage - repair or replace the oil 

pump.

5. Oil spillage barrels, oil pipes and joints - eliminate leakage areas.

6. Oil business card printing dead - check whether the oil spool activity is normal.

injection mould


Second, the melting tube temperature can not be controlled

1. If the temperature cannot be controlled, check whether the contact of the electric heating contactor is sticky, and whether the wire of the thermocouple is loose or damaged.

2. If the temperature cannot rise, check whether the electric heating air switch in the electric box is off, whether the contactor and relay are drawn, whether there is voltage, whether the insurance is burned out, and whether the heating ring is burned out.

3. Check whether the thermometer is damaged.


Three, no mold locking

1. Whether the front opening safety door has been closed, whether the stopper of the safety door has been pressed and loosened 

by the safety door, and whether the wiring is loose or damaged.

2. The mode-locked solenoid coil may have moved inside the valve and stuck the spool -- clean or replace the mode-locked mold 

opening control valve.

3. Direction valve may be out of position - Clean the direction valve.

4. The thimble cannot be returned to reset -- check whether the thimble works normally.

5. Check whether the origin of the mode-locking and mode-opening electronic ruler of the computer controller has changed and 

whether the mode-locking position has terminated.

6. Check whether the pressure gauge works.

7. Press the mode-locking key to see whether the display displays mode-locking signals or other signals and alarms.

8. Check whether the position, speed and pressure of the mold lock are adjusted normally.

9. Check whether the clamping piston rod is broken.


Four, do not shoot glue

1. The coil of the injection solenoid system may have been burned, or there are foreign objects entering the direction valve, and the 

valve core is stuck to move - clean or replace the injection valve.

2. The pressure is too low -- adjust the pressure of the high jet glue.

3. The temperature of injection molding is too low - adjust the thermometer to increase the temperature to the required point, such 

as adjusting the thermometer still can not increase the temperature, check whether the electric heater and fuse are burned out

Or loose break, if broken, timely replacement.

4. The injection combination valve opening system connection is loose or poor contact - the combination switch wire connector is 

properly connected.


Fifth, the glue screw rotates, but the rubber material does not enter the barrel

1. The melt back pressure is too high, the back pressure valve is damaged or improperly adjusted -- adjust or replace the melt back 

pressure valve.

2. Insufficient water transport, so that the temperature is too high, so that the rubber particles into the screw is blocked - adjust the 

water transport, take out the bonded rubber block. See if the water conveyor is blocked or has no cooling water

3. There is no material in the bucket - add material.

4. Whether the melt tube temperature is too high.


Six. The shooting platform does not move

1. The moving limit travel switch of the shooting platform is pressed by the adjusting ram - adjust.

2. The coil of the shooting platform moving solenoid valve may be burned or there are foreign objects entering the direction valve 

stuck in the spool to move - clean or replace the solenoid valve.

3. Check the forward speed of the shooting platform and whether the pressure is improperly adjusted.

4. Check the 1/0 board, the direction valve output voltage (DC+24V) is normal, if not normal, check the corresponding output 

transistor or relay is damaged.

5. Press the station key to check whether the computer display displays the signal in front of the station, or other signals and alarms.

6. Check whether the pressure gauge works.

injection mould


Home
Product
News
Contact
主站蜘蛛池模板: 精品国产亚洲一区二区三区| 亚洲 自拍 另类 欧美 综合| 国产白丝喷水娇喘视频| 亚洲色www成人永久网址| 日本黄页网站免费观看| 免费人成无码大片在线观看| 国产9 9在线 | 中文| 又黄又爽又高潮免费毛片| 日本人妻人人人澡人人爽| 毛片亚洲av无码精品国产午夜| 国产乱子经典视频在线观看| 337p日本欧洲亚洲大胆精品| 国产在线无码一区二区三区| 未满十八勿入av网免费| 国产精品v欧美精品v日韩精品| 亚洲中文字幕无码中字| 中文字幕无码av波多野吉衣 | 中文无码精品a∨在线| 久久频这里精品99香蕉| 久久99精品久久久久久9| 亚洲av日韩av女同同性| 男男gay啪啪网站18禁| 欧美精品videosex极品| 亚洲 欧美 激情 小说 另类| 强行糟蹋人妻hd中文字幕 | 国产∨亚洲v天堂无码久久久| 国产成人无码一区二区在线播放| 国产乱子伦农村xxxx| 巨大黑人极品videos精品| 日日噜噜夜夜狠狠久久无码区| 脱了美女内裤猛烈进入gif | 国产毛片毛多水多的特级毛片| 人妻互换一二三区激情视频| 成熟丰满熟妇av无码区| 免费观看18禁无遮挡真人网站| 18video性欧美19sex高清| 大肉大捧一进一出好爽视频动漫| 国产av一区最新精品| 国产线播放免费人成视频播放| 24小时日本高清www| 中文亚洲成a人片在线观看|